Application
Remote central
station notification
Local alarm
monitoring
Triggering
video surveillance & recording systems
Active relay
for trap door systems
Technical
Specifications
Honeywell ®
IR optical sensor
4 sensitivity
settings for various latch bolt configurations
NO & NC relay
contacts
Single pole,
double throw, Form "C" relay rated at 1- amp at 24 vac
or 24 vdc
Module power
source rating of 12-24 vdc
Current consumption
is 0.034 ampere at 12vdc & 0.045 ampere at 24 vdc
Features
Module is small
enough to tuck away into door frame
Weather resistant
heat sink module
Sensor is concealed
out of sight
Non Mechanical
n Optional on 10 different EN Series Strikes
Ignores ambient
light, detecting reflected IR energy from latch bolt
Quick disconnect
sensor ribbon cable from module for simple strike servicing
Color-coded
wire leads
Optical
Sensor
click on
printable catalog page icon above to view chart
Installation
The sensor module
should be installed so as to eliminate mechanical strain on the
sensor ribbon cable. Excessive strain on this cable can result in
impaired operation. Unused wires should not be clipped off, but
taped back to permit future use if required.
Wiring
Methods/Functions N/C Audio
click on printable
catalog page icon above to view chart
This configuration
uses an audible alarm such as a buzzer to sound alarm when the door
is opened. While the sensor detects the presence of a latch bolt
the relay remains in an open position. Note that the alarm power
source may be AC or DC depending upon the alarm requirements. Note
that the yellow wire (n.o.) is not used.
N/O
Visual
click on printable
catalog page icon above to view chart
This configuration
uses a lighted lamp or led to indicate when the door is secured.
While the sensor detects the presence of a latch bolt the relay
remains in the closed position. The lamp will extinguish when the
door is opened. In this configuration the white wire (n.c.) is not
used. Be sure to use proper series resistance when using led indicators.
Sensitivity
Adjustment (Factory Default)
click on printable
catalog page icon above to view chart
This configuration
uses a lighted lamp or led to indicate when the door is secured.
While the sensor detects the presence of a latch bolt the relay
remains in the closed position. The lamp will extinguish when the
door is opened. In this configuration the white wire (n.c.) is not
used. Be sure to use proper series resistance when using led indicators.
|