EN-400 Premium Electric Strike
For use in new or replacement installation in wood or metal jambs. Use with mortise locks without dead bolts and cylindrical locksets having up to 1" throw.

Replaces Folger Adams 712/732 Cutout



EN-400 PRODUCT
DIMENSIONS




Printable Catalog Page


FEATURES


  • FACE PLATE - ANSI 1-1/4" X 4-7/8"
  • FAIL SECURE/FAIL SAFE: FIELD REVERSIBLE ON DC UNITS
  • ALL STAINLESS STEEL CONSTRUCTION
  • DURABILITY - 1,000,000 LIFE CYLCLES
  • HOLDING FORCE - 2000 lbs. UL tested
  • FIELD ADJUSTABLE - Left or Right Handing in Minutes
  • CAVITY DEPTH - 7/8", CAVITY HEIGHT-1-1/2", CAVITY WIDTH - 3/4"
  • UNIT INSTALLS FLUSH WITH THE FACE OF THE JAMB FOR A TRULY ASTHETIC LOOK
  • MORTISE TYPE- Backset1 11/16" deep

    STANDARDS


  • UL LISTED - 10B fire rated ( Class A, 3-hour Single Swing Doors)
  • UL LISTED - 1034 Burglary Resistant Locking Mechanism for Indoor or Outdoor Use
  • ANSI - 1-1/4"X 4-7/8" Fits cutout Specification A115.1 ( With Slight Jamb Modification)
  • BHMA - A156.5 - 1992 Grade 1

    OPTIONAL FEATURES


  • NEW EN-LB: OPTICAL IR LATCHBOLT SENSOR AVAILABLE
  • EN-CA: Additional coil assemblies available in all voltages listed
  • LOW VOLTAGE BUZZER for audible signal when using DC voltage. Specify BZ-12 for 12 VDC or BZ-24 for 24 VDC.


    FINISH (Specify When Ordering)


  • STANDARD FINISH - Satin Stainless Steel US32D
  • SATIN BRASS - US4
  • BRIGHT BRASS - US3
  • DARK BRONZE - Powder Coated
  • BRIGHT CHROME- US26


    ELECTRICAL CHARACTERISTICS CHART**

    FOUR MAGNETIC COILS AVAILABLE Color coded wires depict the voltage of each coil.
    VOLTAGE
    WIRE COLOR
    12 VAC
    Blue(1) Orange/White(1)
    24 VAC
    Orange(1) Black/White(1)
    12VDC
    Orange/White(2)
    24VDC
    Black/White(2)

     

    FAIL SECURE - NORMALLY LOCKED (Unlocked when energized) Units with AC coils are for Fail Secure (Intemittent duty) use only and should be energized for periods of less than one minute
    VOLTAGE CURRENT
    AMPS
    OHMS SOUND DUTY

    12VAC .70 4.5 Buzz Intm
    24 VAC .37 18.0 Buzz Intm
    12 VDC .28 43.0 Silent Intm/Con
    24 VDC .15 164.0 Silent Intm/Cont

    FAIL SAFE (Reverse Action) NORMALLY UNLOCKED(Locked When Energized) Fail safe action (continuous duty) can only operate with DC coil assemblies. Units with DC coils are field reversible, fail safe action or fail secure continous duty operation. Strikes which are energisezed for periods longer than one minute need to use DC coils.
    VOLTAGE CURRENT/AMPS OHMS SOUND DUTY

    12 VDC .28 43.0 Silent Intm/Cont
    24 VDC .15 164.0 Silent Intm/Cont

    1" throw is based on 1/8” door gap **Specify voltage when ordering


    COMPATIBLE LOCKSETS
    ACCURATE 62, 67, 76
    ADAMS RITE 4700-8300, 8400
    ARROW C, H, M, L
    BEST 5, 7, 50, 6TDL
    CORBIN 9200-9500, UNIT LKS, CL3000, CL4000, ML2200
    DOMINION 300, 400, 5000
    FALCON A, BA, D, E, F, N, S
    HARLOC 49/5900, 6900
    LOCKWOOD 930/970, 8000
    LSDA 1000-1500, 100-150
    MARKS 8000-9000, 5000
    MEDECO EMBASY
    MONARCH 18-M
    NATIONAL 400
    PDQ SR, SV, SX
    PARKER 160A, 9100, L7100, 2800
    RUSSWIN 5400, UNITS LKS, CL3000, CL4000, ML2200
    SARGENT 7700-8100, 6, 7, 8, 9, 10
    SCHLAGE K-L MORT, A, B,D, F
    TACO ED, HV, LXV, SV, MLV
    UNICAN 1000, 6000, 7004
    WEISER A, BA, D, E
    YALE 8600-8700, MONO LK

  •  Return to premium strikes page