FEATURES
FACE PLATE
- ANSI 1-1/4" X 4-7/8"
FAIL SECURE/FAIL
SAFE: FIELD REVERSIBLE ON DC UNITS
ALL STAINLESS
STEEL CONSTRUCTION
DURABILITY
- 1,000,000 LIFE CYLCLES
HOLDING FORCE
- 2000 lbs. UL tested
FIELD ADJUSTABLE
- Left or Right Handing in Minutes
CAVITY DEPTH
- 7/8", CAVITY HEIGHT-1-1/2", CAVITY WIDTH - 3/4"
UNIT INSTALLS
FLUSH WITH THE FACE OF THE JAMB FOR A TRULY ASTHETIC LOOK
MORTISE TYPE-
Backset1 11/16" deep
STANDARDS
UL LISTED -
10B fire rated ( Class A, 3-hour Single Swing Doors)
UL LISTED -
1034 Burglary Resistant Locking Mechanism for Indoor or Outdoor
Use
ANSI - 1-1/4"X
4-7/8" Fits cutout Specification A115.1 ( With Slight Jamb
Modification)
BHMA - A156.5
- 1992 Grade 1
OPTIONAL
FEATURES
NEW EN-LB:
OPTICAL IR LATCHBOLT SENSOR AVAILABLE
EN-CA: Additional
coil assemblies available in all voltages listed
LOW VOLTAGE
BUZZER for audible signal when using DC voltage. Specify BZ-12 for
12 VDC or BZ-24 for 24 VDC.
FINISH
(Specify When Ordering)
STANDARD FINISH
- Satin Stainless Steel US32D
SATIN BRASS
- US4
BRIGHT BRASS
- US3
DARK BRONZE
- Powder Coated
BRIGHT CHROME-
US26
ELECTRICAL CHARACTERISTICS
CHART**
FOUR MAGNETIC
COILS AVAILABLE Color coded wires depict the voltage of each
coil.
|
VOLTAGE
|
WIRE
COLOR
|
|
12
VAC
|
Blue(1)
Orange/White(1)
|
|
24
VAC
|
Orange(1)
Black/White(1)
|
|
12VDC
|
Orange/White(2)
|
|
24VDC
|
Black/White(2)
|
FAIL SECURE
- NORMALLY LOCKED (Unlocked when energized) Units with AC coils
are for Fail Secure (Intemittent duty) use only and should be energized
for periods of less than one minute
| VOLTAGE |
CURRENT
AMPS |
OHMS |
SOUND |
DUTY |
|
| 12VAC |
.70 |
4.5 |
Buzz |
Intm |
| 24
VAC |
.37 |
18.0 |
Buzz |
Intm |
| 12
VDC |
.28 |
43.0 |
Silent |
Intm/Con |
| 24
VDC |
.15 |
164.0 |
Silent |
Intm/Cont |
|
FAIL SAFE
(Reverse Action) NORMALLY UNLOCKED(Locked When Energized) Fail safe
action (continuous duty) can only operate with DC coil assemblies.
Units with DC coils are field reversible, fail safe action or fail
secure continous duty operation. Strikes which are energisezed for
periods longer than one minute need to use DC coils.
| VOLTAGE |
CURRENT/AMPS |
OHMS |
SOUND |
DUTY |
|
|
12 VDC |
.28 |
43.0 |
Silent |
Intm/Cont |
| 24
VDC |
.15 |
164.0 |
Silent |
Intm/Cont |
|
|
1" throw is based on 1/8” door gap **Specify voltage
when ordering |
COMPATIBLE
LOCKSETS
|
| ACCURATE |
62,
67, 76 |
| ADAMS
RITE |
4700-8300,
8400 |
| ARROW |
C,
H, M, L |
| BEST |
5,
7, 50, 6TDL |
| CORBIN |
9200-9500,
UNIT LKS, CL3000, CL4000, ML2200 |
| DOMINION |
300,
400, 5000 |
| FALCON |
A,
BA, D, E, F, N, S |
| HARLOC |
49/5900,
6900 |
| LOCKWOOD |
930/970,
8000 |
| LSDA |
1000-1500,
100-150 |
| MARKS |
8000-9000,
5000 |
| MEDECO |
EMBASY |
| MONARCH |
18-M |
| NATIONAL |
400 |
| PDQ |
SR,
SV, SX |
| PARKER |
160A,
9100, L7100, 2800 |
| RUSSWIN |
5400,
UNITS LKS, CL3000, CL4000, ML2200 |
| SARGENT |
7700-8100,
6, 7, 8, 9, 10 |
| SCHLAGE |
K-L
MORT, A, B,D, F |
|
TACO |
ED,
HV, LXV, SV, MLV |
| UNICAN |
1000,
6000, 7004 |
| WEISER |
A,
BA, D, E |
| YALE |
8600-8700, MONO LK |
|