EN-430 Premium Electric Strike
For use in new or replacement installation in metal jambs. Designed to be used with mortise locks with up to 1" throw* without the need of relocating the centerline.


EN-430 PRODUCT
DIMENSIONS




Printable Catalog Page


FEATURES


  • FACE PLATE - 1-1/4” X 4-7/8”
  • ALL STAINLESS STEEL CONSTRUCTION
  • DURABILITY - 1,000,000 Life cycles
  • HOLDING FORCE - 2000 lbs. UL tested
  • CAVITY DEPTH - 7/8”, CAVITY HEIGHT - 1-1/2”, CAVITY WIDTH - 1"
  • CAVITY CENTERLINE OFFSET 1"
  • HANDED-SPECIFY LH OR RH
  • MORTISE TYPE - Backset 1 3/4" deep


    STANDARDS


  • UL LISTED - 10B fire rated (Class A, 3-hour, Single Swing Doors)
  • UL LISTED - 1034 Burglary Resistant Locking Mechanism for Indoor or Outdoor Use
  • ANSI - 1-1/4” X 4-7/8” Fits Cutout Specification A115.1 (with Slight Jamb Modification)
  • BHMA - A156.5 - 1992, Grade 1


    OPTIONAL FEATURES


  • NEW EN-LB: OPTICAL IR LATCHBOLT SENSOR AVAILABLE
  • EN-CA: Additional coil assemblies available in all voltages listed.
  • LOW VOLTAGE BUZZER for audible signal when using DC voltage. Specify BZ-12 for 12 VDC or BZ-24 for 24 VDC.



    FINISH
    (Specify When Ordering)


  • STANDARD FINISH - Satin Stainless Steel US32D
  • SATIN BRASS - US4
  • BRIGHT BRASS - US3
  • DARK BRONZE - Powder Coated
  • BRIGHT CHROME - US26

    ELECTRICAL CHARACTERISTIC CHART**
    FOUR MAGNETIC COILS AVAILABLE Color coded wires depict the voltage of each coil

    VOLTAGE
    12 VAC
    24 VAC
    12 VDC
    24 VDC
    WIRE COLOR
    Blue(1), Orange/White(1)
    Blue(1), Black/White(1)
    Orange/White(2)
    Black/White(2)



    FAIL SECURE - NORMALLY LOCKED (Unlocked when energized) Units with AC coils are for Fail Secure (Intermittent duty) use only and should be energized for periods of less than one minute
    VOLTAGE CURRENT /
    AMPS
    OHMS SOUND DUTY

    12 VAC .70 4.5 Buzz Intm
    24 VAC .37 18.0 Buzz Intm
    12 VDC .28 43.0 Silent Intm/Cont
    24 VDC .15 164.0 Silent Intm/Cont



    FAIL SAFE (Reverse Action) NORMALLY UNLOCKED (EN430RS) (Locked When Energized) Continuous duty, either Fail Secure or Fail Safe action, need to use DC coil assemblies. Strikes energized for periods longer than one minute are to be considered continuous duty operation. Fail Safe: DC units can be ordered Fail Safe action by adding "RS" to model number. Fail Secure DC units can be changed to Fail Safe action by ordering optional part # EN-SLR-RS.
    VOLTAGE CURRENT/AMPS OHMS SOUND DUTY

    12 VDC .28 43.0 Silent Intm/Cont
    24 VDC .15 164.0 Silent Intm/Cont

    *1” throw based on 1/8” door gap.
    **Specify voltage when ordering


    COMPATIBLE LOCKSETS
    ACCURATE 8500 SERIES
    NT MONARCH 18-M, xx-m, 17-M
    SARGENT 7700-8100
    SCHLAGE L SERIES (L9010-L9082)
    YALE 8700

  •  Return to premium strikes page