EN-800 Rim Exit Device
For use in new or replacement installation in wood or metal single door frames. Use with surface mounted rim exit device with up to 1" throw.


EN-800 PRODUCT
DIMENSIONS




Printable Catalog Page


FEATURES


  • EN-800 FACE PLATE - 1-11/16" X 9" X 3/4"
  • FAIL SECURE/FAIL SAFE: FIELD REVERSIBLE ON DC UNITS
  • ALL STAINLESS STEEL CONSTRUCTION (Stamped Mechanism and Cast Face Plate)
  • Mounting and Mechanism Holes Permit Horizontal Adjustment for Ease of Installation
  • 45º FACE PLATE RAMP - Standard Feature for Deadlocking Latch and Pins
  • HOLDING FORCE - 2000 lbs. UL tested
  • DURABILITY - 1,000,000 Life cycles
  • FIELD ADJUSTABLE - Left or Right Handing In Minutes
  • CAVITY DEPTH - 1-1/4", CAVITY HEIGHT - 1-5/8", CAVITY WIDTH - 3/4"
  • SEMI-MORTISE TYPE - Backset 1 1/4" deep



    STANDARDS


  • UL LISTED - 1034 Burglary Resistant Locking Mechanism for Indoor or Outdoor Use
  • BHMA - A156.5-1992, Grade 1



    OPTIONAL FEATURES


  • NEW EN-LB: OPTICAL IR LATCHBOLT SENSOR AVAILABLE
  • EN-CA: Additional coil assemblies available in all voltages listed.
  • LOW VOLTAGE BUZZER for audible signal when using DC voltage. Specify BZ-12 for 12 VDC or BZ-24 for 24 VDC.



    FINISH
    (Specify When Ordering)


  • STANDARD FINISH - Satin Stainless Steel US32D
  • SATIN BRASS - US4
  • BRIGHT BRASS - US3
  • DARK BRONZE - Powder Coated
  • BRIGHT CHROME - US26


    ELECTRICAL CHARACTERISTIC CHART**

    FOUR MAGNETIC COILS AVAILABLE Color coded wires depict the voltage of each coil

    VOLTAGE
    12 VAC
    24 VAC
    12 VDC
    24 VDC
    WIRE COLOR
    Blue(1), Orange/White(1)
    Blue(1), Black/White(1)
    Orange/White(2)
    Black/White(2)


    FAIL SECURE - NORMALLY LOCKED (Unlocked when energized) Units with AC coils are for Fail Secure (Intermittent duty) use only and should be energized for periods of less than one minute
    VOLTAGE CURRENT
    AMPS
    OHMS SOUND DUTY

    12 VAC .70 4.5 Buzz Intm
    24 VAC .37 18.0 Buzz Intm
    12 VDC .28 43.0 Silent Intm/Cont
    24 VDC .15 164.0 Silent Intm/Cont

    FAIL SAFE (Reverse Action) NORMALLY UNLOCKED (Locked When Energized) Fail safe action (continuous duty) can only operate with DC coil assemblies. Units with DC coils are field reversible, Fail Secure or Fail Safe. AC units must be changed to a DC coil for fail safe action or fail secure continuous duty operation. Strikes which are energized for periods longer than one minute need to use DC coils.
    VOLTAGE CURRENT/AMPS OHMS SOUND DUTY

    12 VDC .28 43.0 Silent Intm/Cont
    24 VDC .15 164.0 Silent Intm/Cont


    **Specify voltage when ordering


    COMPATIBLE LOCKSETS
    ADAMS RITE 8700-8800
    AMERICAN DEVICE
    4300-6300,53
    APR ED22,6000
    ARROW S1200, S3800, S4800, S1800
    CAL-ROYAL 8000
    CORBIN 29, 39, 49, ED8000, 3729, ED9200 4729, ED6200, ED7200
    DOROMATIC 1590/2090, 1090
    JACKSON 2095/1095
    LIBERTY L2000
    LOCKWOOD RC
    MAGNOKROM N1900, N1500, N500/900-1
    MONARCH 19-R, 18-R, 17-R, 11-R, XX-R
    PARKER UL520, 505-DUR
    PRECISION

    101

    REED 900/9100, 9200/3050, 1300/4000
    RUSSWIN 372/472, ED8000, 572/736, ED9200, 635, ED6200, ED7200
    SARGENT 2810, 8510, 8810/8888, 9810
    TACO ED500, ED-301
    VON DUPRIN 22, 33, 55, 88, 98, 99
    YALE 1500/2200, 7000/7100, 7200